Physiology · Phase 1

Cardiac Output

Definition, normal values, stroke volume and cardiac index, determinants, control by venous return, Frank-Starling mechanism, exercise, high and low output states and measurement.

NMC competency
PY5.10
Region
Cardiovascular system
Reading time
14 min
Comes with
6 MCQs · viva · flashcards

Quick answer: Cardiac output is the volume of blood pumped by each ventricle in one minute. It equals heart rate multiplied by stroke volume. A resting adult averages about 5 L/min, from roughly 70 mL per beat at 72 to 75 beats per minute. Under normal conditions it is controlled mainly by venous return, which is the sum of all local tissue blood flows.

Definition and formula

Cardiac output (CO) is the amount of blood pumped by each ventricle in 1 minute. It is also the quantity of blood that flows through the circulation. Because it is the sum of the blood flow to all the tissues of the body, it is one of the most important factors in how the cardiovascular system functions.

It is the product of heart rate and stroke volume:

CO = HR x SV

  • Heart rate (HR) is the number of heartbeats per minute.
  • Stroke volume (SV) is the amount of blood pumped out by a ventricle with each beat.

Worked example: HR 75 beats/min x SV 70 mL/beat = 5,250 mL/min, or about 5.25 L/min. Using 72 beats/min gives about 5.0 L/min.

Stroke volume can be calculated back from cardiac output: SV = CO (L/min) x 1000 divided by HR. Its normal range is given as 60 to 90 mL per beat.

Cardiac reserve is the difference between resting and maximal cardiac output.

Normal values

MeasureTypical value
Stroke volume (resting, supine, average-sized man)About 70 mL from each ventricle
Cardiac output, resting adultAbout 5 L/min in round numbers. A normal adult at rest ranges from 4.0 to 6.5 L/min.
Young healthy menAbout 5.6 L/min
WomenAbout 4.9 L/min
Cardiac indexNormal 2.5 to 3.5 L/min per square metre of body surface area; the average is about 3.2 L/min/m2

Cardiac index

Resting cardiac output correlates with body surface area. So output is divided by body surface area to correct for the size of the patient. This gives the cardiac index, the output per minute per square metre of body surface.

What changes cardiac output in life?

Cardiac output varies widely with activity. Among the factors that directly affect it are:

  1. The basic level of body metabolism
  2. Whether the person is exercising
  3. The person's age
  4. The size of the body

With increasing age, activity and the mass of some tissues, such as skeletal muscle, decrease, so cardiac output falls.

What determines cardiac output?

Because CO = HR x SV, any change in output must come from a change in heart rate, stroke volume, or both.

  • Heart rate is controlled mainly by the autonomic nerves. Sympathetic stimulation increases the rate and parasympathetic stimulation decreases it.
  • Stroke volume is partly determined by neural input too. Sympathetic stimulation makes the myocardial fibres contract more strongly at any given length.

More fully, cardiac output is determined by preload, afterload, heart rate, contractility and ventricular compliance. Cardiac output rises with an increase in heart rate, preload or contractility, and with a decrease in afterload.

Up or down? Output goes up with higher heart rate, preload and contractility. It goes up with lower afterload, and it goes down with higher afterload.

Contractility is hard to define in an intact heart because it cannot be separated from loading conditions. The Frank-Starling relationship is defined as the change in the intrinsic contractile performance of the heart in response to changes in preload.

Venous return and cardiac output

Venous return is the quantity of blood flowing from the veins into the right atrium each minute. Cardiac output and venous return must equal each other, except for a few heartbeats when blood is temporarily stored in or taken from the heart and lungs.

Under most normal, unstressed conditions, the cardiac output is controlled mainly by peripheral factors that determine venous return, not by the heart itself. The reasoning runs like this:

  • Venous return is the sum of all the local blood flows through every tissue of the peripheral circulation.
  • In most tissues, local blood flow increases in proportion to the tissue's metabolism. For example, local flow almost always increases when tissue oxygen consumption goes up.
  • So cardiac output is normally the sum of all the local blood flow regulations.

During exercise, oxygen consumption and cardiac output rise in parallel.

The heart becomes the limiting factor only if more blood returns than the heart can pump.

Frank-Starling mechanism and Bainbridge reflex

When more blood returns to the heart, the heart pumps more. The Frank-Starling mechanism is the heart's intrinsic ability to increase its output in response to greater filling. In addition, the stretched right atrium starts a nervous reflex, the Bainbridge reflex. It passes first to the vasomotor centre of the brain and then back to the heart along the sympathetic nerves and the vagi, and it increases the heart rate.

Total peripheral resistance

Over the long term, cardiac output is related to total peripheral resistance in the opposite direction. When total peripheral resistance rises above normal, cardiac output falls. When it falls, cardiac output rises. This follows Ohm's law. If long-term total peripheral resistance changes and nothing else in the circulation changes, cardiac output changes by the same amount in exactly the opposite direction.

Arterial pressure is related to the two: mean arterial pressure is the product of cardiac output and systemic vascular resistance.

Cardiac output curve and venous return curve

For a more quantitative picture, two factors are looked at separately:

Graph of cardiac output and venous return curves crossing at an equilibrium point.
Cardiac output and venous return curves meet at the equilibrium point.Persichini, Romain Lai, Christopher Teboul, Jean-Louis Adda, Imane Guérin, Laurent Monnet,, CC BY 4.0, via Wikimedia Commons
  1. The pumping ability of the heart, shown by the cardiac output curve
  2. The peripheral factors that affect flow of blood from the veins into the heart, shown by the venous return curve

When the two curves are plotted together, they cross at only one point, the equilibrium point. At that point venous return equals cardiac output and the right atrial pressure is the same for the heart and the systemic circulation. In a normal circulation the equilibrium point gives a cardiac output of 5 L/min and a right atrial pressure of 0 mm Hg.

The heart has definite limits to how much blood it can pump, and these limits are what the cardiac output curve shows.

Shifting the cardiac output curve

A heart can be hypoeffective (weaker than normal) or hypereffective (stronger). Factors that reduce the heart's ability to pump include:

  • Severe hypertension, which raises the pressure the heart must pump against
  • Inhibition of nervous excitation of the heart
  • Abnormal heart rhythm or rate
  • Coronary artery blockage causing a heart attack
  • Valvular heart disease
  • Congenital heart disease
  • Myocarditis (inflammation of the heart muscle)
  • Cardiac hypoxia

The pressure outside the heart also shifts the curve. Positive-pressure breathing and opening the chest shift it to the right. Cardiac tamponade, a large collection of fluid in the pericardial cavity, also shifts it to the right because it raises the pressure outside the heart.

Cardiac output in exercise

During exercise, cardiac output may rise several-fold. The sympathetic nerves to the heart have two effects:

  • The heart rate rises, up to as high as 170 to 190 beats per minute
  • The strength of contraction rises, up to as much as twice normal

If only the normal heart's plateau were available, the rise in cardiac output would be limited to about 2.5 times. In practice, an untrained runner commonly reaches a 4-fold increase and some marathon runners reach a 7-fold increase. The venous return curve must also change, because its normal upper plateau is only 6 L/min.

During exercise, the nervous system also raises arterial pressure above normal, which adds a further 30% to 100% to the cardiac output.

Distribution of cardiac output

The cardiac output is shared among organs. The figures for the whole of the systemic output are:

OrganShare of cardiac output
Liver24%
Muscle23%
Kidneys20%
Brain12%
Intestines8%
Skin6%
Heart4%

High and low output states

High cardiac output

The conditions that cause an abnormally high cardiac output all arise from a chronically reduced total peripheral resistance. None of them is caused by excessive excitation of the heart itself.

  • Beriberi: a lack of thiamine (vitamin B1) reduces the ability of tissues to use some nutrients. Local flow-control mechanisms respond with marked peripheral vasodilation. Total peripheral resistance may fall to as little as half of normal, and cardiac output may rise to twice normal.
  • Arteriovenous (AV) fistula: blood flows from a large artery straight into a large vein, bypassing most of the peripheral resistance. In the example described, output rises from 5 L/min up to 13 L/min at once, then to almost 16 L/min when the sympathetic reflexes restore arterial pressure, and later to almost 20 L/min as the kidneys retain salt and water and the heart muscle hypertrophies slightly.
  • Other conditions with high output: hyperthyroidism, anaemia, pulmonary disease, Paget's disease, and pregnancy. In anaemia, two peripheral effects greatly decrease resistance. One of them is diminished delivery of oxygen to the tissues, which causes local vasodilation.

Low cardiac output

Low output falls into two groups: abnormalities that decrease the pumping effectiveness of the heart, and those that decrease venous return.

Cardiac factors (the damaged heart): severe coronary blockage with myocardial infarction, severe valvular disease, myocarditis, cardiac tamponade and cardiac metabolic derangements.

Peripheral (non-cardiac) factors, which decrease venous return:

  • Decreased blood volume, the most common cause
  • Acute venous dilation, in which blood pools in the vessels and does not return to the heart as fast as normal
  • Obstruction of the large veins, which is rare

Output also falls when the tissue metabolic rate is reduced, for example in muscle during prolonged bed rest, or in hypothyroidism.

If output falls below the level needed to nourish the tissues, the person is in circulatory shock, which can be lethal within a few minutes to a few hours. When this is due to a failing heart, it is called cardiac shock.

In the critically ill, a heart rate that is too fast can reduce output because there is less time for diastolic filling, and it also raises myocardial oxygen demand.

Measuring cardiac output

In animal experiments, flow can be measured with an electromagnetic or ultrasonic flowmeter on the aorta or pulmonary artery. In humans it is usually measured by indirect methods that do not need surgery. Accurate assessment is especially important in critically ill patients and in high-risk patients undergoing surgery. Clinical assessment alone is often inaccurate, since a seriously ill patient with low output may have a normal systemic arterial pressure.

MethodPrinciple
Fick principleBased on conservation of mass. The oxygen taken up by the lungs is calculated from the difference between oxygen content in arterial and mixed venous blood, and this gives the flow. Normal arteriovenous oxygen difference is 30 to 50 mL/L.
Indicator (dye) dilutionA known amount of an indicator is injected into the bloodstream, and the average concentration over the time it takes to pass is measured. Flow equals the amount injected divided by the average concentration and the time. A shunt changes the shape of the curve: right-to-left shunts distort the build-up slope, and left-to-right shunts reduce the peak and remove the recirculation peak.
ThermodilutionCold saline (room temperature or iced) is injected into the right atrium or inferior vena cava through a flow-directed, thermistor-tipped pulmonary artery (Swan-Ganz) catheter. The temperature change is detected downstream in the pulmonary artery. It is a variant of the indicator dilution method and is considered the gold standard in practice. It is used in patients without shunts.
Doppler ultrasonographyMeasures the velocity of blood in the aorta or the pulmonary artery outflow tract. Output is the average velocity multiplied by the cross-sectional area.
Impedance plethysmographyFour electrodes on the neck and chest detect changes in impedance with each beat that correlate with stroke volume. Electrode placement is an important source of error. It has not gained wide acceptance.

Mnemonic

Cardiac output in one line: CO = HR x SV, and in the healthy body it follows venous return, which follows tissue metabolism.

Practice MCQs

A resting adult has a heart rate of 75 beats/min and a stroke volume of 70 mL. The cardiac output is approximately:

  • A. 0.5 L/min
  • B. 2.5 L/min
  • C. 5.25 L/min
  • D. 10 L/min
Show answer

Answer: C. Cardiac output is the product of heart rate and stroke volume. At 75 beats per minute and 70 mL per beat, it is 5,250 mL/min, or about 5.25 L/min.

Cardiac index is calculated by dividing cardiac output by:

  • A. Body surface area
  • B. Heart rate
  • C. Stroke volume
  • D. Mean arterial pressure
Show answer

Answer: A. Cardiac index is cardiac output divided by body surface area, which corrects the output for the size of the person.

Which of the following would decrease cardiac output?

  • A. Increased preload
  • B. Increased contractility
  • C. Decreased afterload
  • D. Increased afterload
Show answer

Answer: D. Cardiac output rises with higher heart rate, preload and contractility. It falls when afterload increases, so a decrease in afterload raises output.

Under normal resting conditions, cardiac output is controlled mainly by:

  • A. The strength of contraction of the heart alone
  • B. Venous return, which reflects tissue metabolism
  • C. The heart rate alone
  • D. The pressure in the pericardial cavity
Show answer

Answer: B. In normal unstressed conditions the output is controlled mainly by peripheral factors that set venous return. Venous return is the sum of all the local tissue blood flows, which follow local metabolism.

Beriberi, a large arteriovenous fistula and anaemia all cause a high cardiac output because they:

  • A. Strongly excite the heart directly
  • B. Raise the blood volume
  • C. Chronically reduce total peripheral resistance
  • D. Obstruct the large veins
Show answer

Answer: C. High output states such as beriberi, AV fistula and anaemia arise from chronically reduced total peripheral resistance. Low peripheral resistance allows more venous return, so output rises.

The method regarded as the gold standard for measuring cardiac output in clinical practice is:

  • A. Thermodilution
  • B. Impedance plethysmography
  • C. Palpation of the pulse
  • D. Measurement of systemic arterial pressure
Show answer

Answer: A. The thermodilution method uses a flow-directed pulmonary artery catheter and injected cold saline, and it is considered the gold standard for clinical measurement. It is used in patients without shunts.

Viva questions

Define cardiac output and give its formula.

It is the volume of blood pumped by each ventricle per minute. Cardiac output equals heart rate multiplied by stroke volume.

What is the normal resting cardiac output and stroke volume?

About 5 L/min in an adult, with a stroke volume of about 70 mL per beat. The usual range at rest is 4.0 to 6.5 L/min.

What is cardiac index?

Cardiac output per minute per square metre of body surface area. The normal value is 2.5 to 3.5 L/min/m2.

What is cardiac reserve?

The difference between the resting and the maximal cardiac output.

What are the determinants of cardiac output?

Preload, afterload, heart rate, contractility and ventricular compliance. Output rises with an increase in heart rate, preload or contractility and with a decrease in afterload.

What is the Bainbridge reflex?

A stretched right atrium sends signals to the vasomotor centre, and the sympathetic nerves and vagi carry them back to the heart to increase the heart rate.

How is cardiac output measured clinically?

By the Fick principle, indicator dilution, thermodilution (the gold standard, using a pulmonary artery catheter), Doppler ultrasonography or impedance plethysmography.

Flashcards

Still unsure how venous return controls cardiac output? Ask the GalenAI tutor and practise cardiac output MCQs.

More physiology lessons.

All physiology →

Preparing for a PG entrance? Practise free MCQs or read the NEET PG guide.

Sources

  • Standard physiology, anaesthesia and critical care references
  • Image credits are given under each figure. All images are openly licensed.